Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 84(3): 214-219, May-June 2021. graf
Article in English | LILACS | ID: biblio-1248961

ABSTRACT

ABSTRACT Purpose: To evaluate the influence of pupil dynamics on the defocus profile and area-of-focus of eyes implanted with a diffractive multifocal intraocular lens (IOL). Methods: This prospective randomized trial was conducted at the Department of Ophthalmology, School of Medicine of Ribeirão Preto, University of São Paulo, Brazil. Thirty-eight patients were randomly assigned to receive the multifocal SN6AD1 (n=20) or the aspheric monofocal SN60WF (aIOL) (n=18) IOLs bilaterally. Dynamic pupillometry, visual acuity for distance and near, corrected and uncorrected, and a defocus profile were assessed postoperatively. The area-of-focus was calculated using an empirical polynomial model of the defocus profile. Results: Sixteen patients (32 eyes) in the multifocal SN6AD1 group and 17 patients (34 eyes) in the aspheric monofocal SN60WF group completed the 1-year follow-up. There were no significant between-group differences in monocular uncorrected distance or near visual acuity. The defocus profiles of the mfIOL group showed a double peak, whereas those of the aspheric monofocal SN60WF group showed only one peak, which is typical for a monofocal intraocular lens. The area-of-focus of the aIOL group (4.66 ± 1.51 logMARxD) was significantly different from that of the multifocal SN6AD1 (1.99 ± 1.31 logMARxD). Pupil size at maximum contraction after exposure to a flash of 30 cd/m2 for 1 second was significantly correlated with a better area-of-focus in the multifocal SN6AD1 group (r=0.54; p=0.0017), whereas this was not the case in the aspheric monofocal SN60WF group. Conclusion: These findings indicate that in eyes implanted with an multifocal SN6AD1, the smaller the pupil size, the better is the area-of-focus and hence the better is the visual performance. This correlation was not found for the aspheric monofocal SN60WF.(AU)


RESUMO Objetivo: Avaliar a influência da dinâmica pupilar na curva de desfoco de olhos implantados com lente intraoculares multifocais difrativas. Métodos: Estudo prospectivo e randomizado realizado na Faculdade de Medicina de Ribeirão Preto - Universidade de São Paulo - Departamento de Oftalmologia. Trinta e oito pacientes foram aleatoriamente designados para receber bilateralmente lentes intraoculares SN6AD1 (n=20) (mfIOL) ou SN60WF (n=18) (aIOL). Além da acuidade visual para longe e perto, corrigida e não corrigida, e curva de desfoco, foi ainda realizada pupilometria dinâmica. A área sob a curva de desfoco foi calculada usando um modelo polinomial empírico. Resultados: Um total de 16 e 17 pacientes (n=32 e 34 olhos) completaram 1 ano de seguimento nos grupos mfIOL e aIOL, respectivamente. Não houve diferenças significativas entre grupos para as acuidades visuais seja para longe ou perto. As curvas de desfoco do grupo mfIOL mostraram um pico duplo; enquanto o SN60WF mostrou apenas um pico, típico para uma lente intraoculares monofocal. A média da área sob a curva de desfoco do grupo aIOL foi (4,66 ± 1,51 logMAR.dp), e essa é estatisticamente significante diferente da métrica do grupo mfIOL (1,99 ± 1,31 logMAR.dp). A pupila na contração máxima após a exposição a um flash de 30 cd/m2 por 1 segundo foi significativamente correlacionada com uma melhor área de foco no grupo mfIOL (r=0,54; p=0,0017), essa relação não foi observada para o grupo aIOL. Conclusão: Estes dados indicam que quanto menor a pupila durante contração, melhor é a área sob a curva de desfoco e, portanto, o desempenho visual dos olhos implantados com essa mfIOL. Esta correlação não foi encontrada para lentes intraoculares monofocais.(AU)


Subject(s)
Humans , Cataract Extraction , Pupil/physiology , Phacoemulsification/instrumentation , Multifocal Intraocular Lenses , Prospective Studies
2.
Arq. bras. oftalmol ; 76(5): 274-277, set.-out. 2013. ilus
Article in English | LILACS | ID: lil-690603

ABSTRACT

PURPOSE: To investigate the correlation between the measurements of the cup/retrobulbar optic nerve diameter (C/OND) proportion obtained by high-resolution 20-MHz B-mode ultrasound (US) and those of the cup/disc ratio (C/D) obtained by fundus biomicroscopy (BIO) and optical coherence tomography (OCT). METHODS: Thirty eyes of 15 glaucomatous patients with any C/D proportion were studied. All patients underwent examination of the vertical C/D by BIO with a 78D lens and time-domain OCT analysis, as well as the vertical C/OND proportion using 20-MHz US measurements. All data were analyzed by correlation and agreement tests. RESULTS: The Spearman test showed a strong correlation between C/D results obtained by BIO and the measurements of C/OND (US) (r=0.788, p<0.0001), and with C/D obtained by OCT (r=0.8529, p<0.0001). However, comparison of C/D results obtained with OCT to those obtained by with C/OND (US) showed only a moderate correlation (r=0.6727, p<0.0001). Bland-Altman analysis did not show good agreement between C/D (BIO) and C/OND (US). CONCLUSIONS: The results demonstrate that B-mode ultrasound examination with a 20 MHz probe can be a good additional method for the evaluation of the C/D ratio in glaucomatous patients, and may be considered as an alternative gross tool in glaucomatous patients with optic media opacities.


OBJETIVOS: Verificar a correlação entre os achados da relação escavação/diâmetro do nervo óptico retrobulbar (E/DNO) obtidos pelo exame de ultrassom (US) modo B de alta resolução com sonda de 20 MHz e a relação escavação/disco (E/D) obtidos pela biomicroscopia de fundo de olho (BIO) e pela tomografia de coerência óptica (OCT). MÉTODOS: Foram analisados 30 olhos de 15 pacientes com diagnóstico de glaucoma com qualquer proporção da relação E/D. Todos os pacientes foram submetidos ao exame de BIO, com lente 78D, e de OCT, com tecnologia de domínio temporal, para a análise da relação E/D vertical e exame de US modo B, com sonda de 20 MHz, para determinação da proporção E/DNO vertical. Todos os resultados foram analisados por métodos de correlação e concordância. RESULTADOS: Observou-se forte correlação entre as medidas E/D obtidas pela BIO, e as medidas E/DNO (US) (r=0,788; p<0,0001), e com as medidas E/D obtidas pelo OCT (r=0,8529; p<0,0001). Porém, a análise entre as medidas E/DNO (US) e E/D (OCT) mostrou apenas níveis moderados de correlação (r=0,6727, p<0,0001). O teste de Bland-Altman não mostrou bons níveis de concordância entre E/D (BIO) e E/DNO (US). CONCLUSÕES: Os resultados demonstraram que o exame de US modo B com sonda de 20 MHz pode ser um bom método adicional para avaliar a relação E/D de pacientes com glaucoma, a ser considerado como uma ferramenta alternativa na avaliação de pacientes glaucomatosos com opacidades dos meios ópticos.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Glaucoma , Microscopy, Acoustic/methods , Optic Nerve , Corneal Opacity , Cross-Sectional Studies , Fundus Oculi , Optic Disk , Statistics, Nonparametric , Tomography/methods
SELECTION OF CITATIONS
SEARCH DETAIL